We have received so many below alerts this weekend due to relocation failure due to less then 10% space left in pool.
Received alerts like “FAST VP relocations fail with error code 712d841a with extended code 0xe12d8709.”
Time Stamp 05/22/12 10:39:04 (GMT) Event Number 712d841a Severity Error Host SPB Storage Array FCN00120xxxxxx SP N/A Device N/A Description Internal Information Only. Could not complete operation Relocate 0xB00000D5A allocate slice failed becauseĀ 0xe12d8709.
00000400 03002c00 d3040000 1a842de1 1a842de1 00000000 00000000 00000000 00000000 00000000 712d841a
SAN : EMC VNX5300 / VNX Operating Environment (OE) 7.x
Solution :
The following steps i have done to fix the email alerts issue:
- Stop using the custom template.
- Export the template.
- Modify the template manually with a text editor andĀ replace:
Event
{
Min 0x712d8000
Max 0x712dbfff
Threshold 1
Interval 1
}with
Event
{
Min 0x712d8000
Max 0x712d8419
Threshold 1
Interval 1
}
Event
{
Min 0x712d841b
Max 0x712dbfff
Threshold 1
Interval 1
} - Delete the old template.
- Import the new template.
Apply the new