Author name: admin

TDP Exchange mailbox store exclusion

Instead of just one line like this: tdpexcc backup * full have mulitple lines like this: tdpexcc backup <STORE_1_NAME> full tdpexcc backup <STORE_2_NAME> full tdpexcc backup <STORE_3_NAME> full Full Scripts We Use: @ECHO OFF rem  ================================================================== rem   Sample Command File – excfull.smp rem rem   Sample command file containing commands to do a scheduled rem   full

TDP Exchange mailbox store exclusion Read More »

VNX not able to login in glogal domain or Control Station

Problems : Uninitializing and recreating the VNX Unified/File domain for both the Block and File  components EMC SW: VNX Operating Environment (OE) for Block 05.31.000.5.502 and later EMC SW: VNX Operating Environment (OE) for File 7.0.35.3 and later Product: VNX File/Unified /nas/http/webui/bin/domain_admin Security not initialized on the storage system. issue the Control Station and the

VNX not able to login in glogal domain or Control Station Read More »

Tuning for Oracle Database on UNIX

Operating System Tools Several operating system tools are available to help you assess database performance and determine database requirements. In addition to providing statistics for Oracle processes, these tools provide statistics for CPU usage, interrupts, swapping, paging, context switching, and I/O for the entire system. Common Tools The following sections provide information on common tools:

Tuning for Oracle Database on UNIX Read More »

VxVM Troubleshooting – Procedure to Replace Internal FibreChannel (FC) Disks controlled by VxVM

Hot swapping of a failed disk is fairly straight procedure if the disks are regular SCSI disks, but for the Fibre Channel (FC) disks we should follow different procedure for hot swaping. Below specific procedure should be used when replacing one of the internal disks in a system with internal fibre drives (Sun Fire 280R,

VxVM Troubleshooting – Procedure to Replace Internal FibreChannel (FC) Disks controlled by VxVM Read More »

OSSEC v2.0 commands

ossec-reportd is a program to create reports from OSSEC alerts. ossec-reportd accepts alerts on stdin, and outputs a report on stderr. Note Since ossec-reportd outputs to stderr some utilities like less will not work if you do not redirect the output. End the ossec-reportd with 2>&1 to redirect stderr to stdout. more or less can

OSSEC v2.0 commands Read More »

RHCE "Cheat Sheet"

This document attempts to provide answers to all study points on the RHCE and RHCT Exam Preparation Guide in a single-page (and thus, printable) format. This is not a “brain dump” or an attempt to cheat the RH302 exam in any way. These are just my self-study notes. Use them at your own risk. Other

RHCE "Cheat Sheet" Read More »

Cisco MDS Series Switch CLI – Config Mode Commands Line Interface

The following example shows output from the config terminal command: switch# config terminal Enter configuration commands, one per line. End with CNTL/Z. switch(config)# Configuration Mode Commands and Submodes Here is a list of configuration mode commands: switch# config terminal Enter configuration commands, one per line. End with CNTL/Z. switch(config)#   aaa Configure the aaa arp

Cisco MDS Series Switch CLI – Config Mode Commands Line Interface Read More »